• Check calibration of your instrument annually to ensure it meets original performance specifications

• Keep your instrument dry. If it gets wet, wipe dry immediately. Liquids can degrade electronic circuits

• Whenever practical, keep the instrument away from dust and dirt that can cause premature wear

• Although your instrument is built to withstand the rigors of daily use, it can be damaged by severe

impacts. Use reasonable caution when using and storing the meter.

p

eriodiC

S

erviCe

WARNING!

Repair and service of this instrument is to be performed by qualified personnel only. Improper repair

or service could result in physical degradation of the instrument. This could alter the protection from per-

sonal injury this meter provides to the operator. Perform only those maintenance tasks that you are qualified to

do.

a

NNual

r

e

-C

alibratioN

While the sensors have an expected life of more than five years in normal use it is recommended that the

analyzer is re-calibrated annually. This is so that long-term drift can be eliminated. Local regulations may

require more frequent re-calibration and users should check with appropriate authorities to ensure

compliance with relevant guidelines.

C

leaNiNg

Periodically clean your instruments case using a damp cloth. DO NOT use abrasive, flammable liquids,

cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of

the structural components.

e

mptyiNg

& C

leaNiNg

the

i

N

-l

iNe

w

ater

t

rap

The in-line water trap should be checked and emptied on a

regular basis. Water vapor will condense in the probe line,

which may cause the water trap to fill suddenly if the probe

is moved. Care should be taken at all times.

Carefully un-screw the plug from the bottom of the

water-trap housing. Dispose of the condensate in a suitable

drain, care must be taken as it could be acidic. If conden-

sate spills onto the skin or clothing, clean off immediately

using fresh water, seek medical advice if problems occur.

Ensure plug is replaced before performing combustion

tests. Note: CO2 reading will be low if the Water Trap

Plug is not in place.

C

haNgiNg

t

he

p

artiCle

f

ilter

This is a very important part of the analyzer and should be changed regularly. It prevents dust and dirt

particles from entering the pump and sensors that will cause damage. The filter MUST be changed when it

appears discolored on the inner surface.

Remove water-trap assembly from the analyzer as shown

above. Remove the filter and plastic holder from the housing.

Discard the filter element but keep the holder to fit to the new

filter. Clean the inside of the filter housing with a suitable soft

cloth. Fit the holder onto the new filter element and then insert

into the housing. Refit the housing onto the analyzer.

Hook slides

out of dock

Slide outward

Unscrew plug

to drain

3

Insert a new filter