Ultravation Photronic HEPA Portable Room Air Purifier - DC-IH-0211 User Manual

Page 3

Advertising
background image

3

Maintenance:

The filter media in your air cleaner must be changed
periodically. The frequency of filter replacement is best
determined by visual examination. However, a 60 day
replacement of the 2” filter and 5 years for the HEPA
filter is strongly recommended. Replacement filters
obtained through your installing contractor or local
dealer. - Actual replacement may vary depending on
the severity of dust and dirt particles.

If the Photocatalytic filter should become dirty, it
may be cleaned with low velocity compressed air
or vacuum only, no solvents or water should be
used
. If the Photocatalytic section becomes wet, allow
the section to air dry before reinstallation.

The mesh screen on the Photocatalytic filter is coated
using a patented process known to photo chemically
breakdown VOC’s and Odors as well as reduce
airborne pathogens on contact. Under normal operating
conditions this filter should not require replacement
within five years and may last up to 10 years.
.
The Air cleaner should never be run with a filter with
less than a MERV-11* Filter.

Using less than a MERV-11* Filter rating will reduce
the effectiveness of this product. It is recommended
that this product be serviced and maintained by an
HVAC professional.

*MERV or Minimum efficiency rating value is a number
assigned to filters indicating their ability to capture
particles and dust, the higher the number the better the
filter. A MERV 11 filter is 40% more effective than a
MERV-8. Be sure that an Ultravation MERV-11 filter is
requested for replacements in this product.

Steps for replacing filters:

Pleated Media Filter:


1. Open the access door by lifting up and pulling
toward you, removing door completely.

2. Pull out media filter and discard.

3. Slide new media filter into cabinet with “airflow label
pointing in the direction of the airflow. Be sure to seat
new filter into left and right guide rails to assure a good
seal.

4. Replace access door.

Note: a gasket is provided to seal between the opening
on the side of the filtration cabinet and the side of the
air handler.

Aluminum PCO Filter:


Follow steps 1

2. Remove the HEPA filter completely from the

cabinet.


3. The PCO filter is located underneath the

electronics tray. Remove the tray from the
cabinet half way, slide electronics tray back
leaving PCO screen sticking out of cabinet.
Remove screen completely.


4. Replace or clean filter, then reverse and repeat

last two steps.

5. Replace access door.

Steps for replacing Photocatalytic lamps:

1. Turn the systems power off.

2 Remove cabinet access door.

3. Locate the lamps underneath HEPA filter, remove
rubber boot from lamp base.

4. Remove the 2 screws from the ceramic lamp base.

5. Remove lamps completely from electronics tray.
Reverse the process with new lamps. (New lamps
should be cleaned with a damp cloth or with
rubbing alcohol to remove any fingerprints and
debris prior to installation.)