Ultravation Photronic HEPA Portable Room Air Purifier - DC-IH-0211 User Manual

Page 4

Advertising
background image

4

Replacement Parts:


MERV 11 Filter 650 CFM p/n: 91-010
HEPA Filter 650 CFM p/n: 91-011

(See Serial Number Label on inside of equipment door for unit replacement part numbers)

13 1/2” x 17” x 1/2” PCO Filter p/n: 91-042
Photo Catalytic UVC Lamps p/n: AS-IH-1001

Warranty:

Ultravation warrants this product against any defects in material or workmanship for a period of 10 years after date of
purchase, with the exception of the disposable media filter, the UV Lamps, the battery, the ductwork and installation.
The UV lamps and the battery are warranted for a period of 1year.

This warranty does not include damage to the unit from accident, misuse or improper installation. If this product
should become defective during the warranty period, Ultravation will repair or elect to replace the product free of
charge. Ultravation will return repaired or replaced warranted products pre-paid, provided that the product was
delivered pre-paid.

Ultravation shall have no responsibilities for charges incurred by the customer for installation or removal of warranted
items. Liability is limited only to the replacement or repair of this product.

This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
All returns must be accompanied by a return authorization number, which may be obtained by contacting Ultravation,
Inc.

Ultravation, Inc.~ P.O. Box 165 ~ 212 Ideal Way ~ Poultney, Vermont 05764
Phone: 802-287-9735 ~ Fax: 802-287-9203 ~ www.ultravation.com

Troubleshooting:

Important information: It is a normal characteristic of
all UV lamps to blacken around the filaments (ends) of
the lamp. This does not signify the lamp is defective or
not emitting Ultraviolet light.

The only time a UV lamp is defective is if it will not
light. UV Lamps that illuminate will not qualify for
Warranty.


Check for any loose or disconnected wiring

Lamps are securely plugged into their sockets

Verify the unit has power (120 or 240 volts) and the
Power switch is in the ON position

The electronic circuit of a 3-lamp system only operates
when both lamps are operating.

Verify if in fact the UV lamps are on or off. Do not
look at the UV light without proper eye
protection.

Note:


In this case a service technician should be contacted.

Please contact your local dealer or HVAC contractor
for replacement lamps.

There are NO user serviceable replacement parts
other than the lamps.

Refer servicing to qualified service personnel.

Advertising