Mvip b, Csu (c, T1 b – AltiGen comm TRITON T1 User Manual

Page 3

Advertising
background image

S

TEP

3: C

ONNECT

T

HE

M

VIP

C

ABLE AND

T

ERMINATE

T

HE

MVIP B

US

S

TEP

4: C

ONNECT

CSU (C

HANNEL

S

ERVICE

U

NIT

)

TO

T

RITON

T1 B

OARD

Using Adtran’s CSU (model T1 CSU ACE) as an example, connect your CSU to

the Triton T1 board using on RJ-48C or RJ-48X cable. Then, connect your CSU

to your network termination box using an RJ-48C or RJ-48X cable.

The MVIP Bus is only terminated on one board per system.

IMPORTANT! Make sure the MVIP bus is terminated (set to close) at the

Quantum Board with ID of 0. All other boards are not terminated (MVIP Bus

Termination Switch set to OPEN). DO NOT TWIST THE MVIP

CABLE. It should lay flat when connected to boards, as shown below.

Quantum

Triton

CPU Board

MVIP Bus Termination

Switch CLOSE

OPEN

CLOSE

Power

RJ48c or

RJ-48x cable

RJ48c or

RJ-48x cable

Network

Termination

Box

Central

Office

Net

T1 Line

CSU

CPE

For T1 Socket (RJ-48)
Receive Ring = Pin 1
Receive Tip = Pin 2
Transmit Ring = Pin 4
Receive Tip = Pin 5

0 1

CPU

3 2 1 0

For Adtran CSU
NOTE: The default settings for the equipment Line Build Out (LBO) and the network
LBO are for distances shorter than 133 ft.
CAUTION: Switch ON the Manual Loopback (LB) when the equipment connection
(from the Triton Board) is not ready. This will give the CO good signal and prevent the
CO from switching off service. Switch OFF the Manual LB in normal operation.