LV-8235 UST Basic Serial Command Specifications

-22-

7.5. Input Mode Read Command

Command “CR1”

[CR]

Detail

Get the selected Input No.

Response

Acceptable “%1”

[CR]

%1

”1” = Computer 1 is selected
”2” = Computer 2 is selected
“3” = HDMI is selected
“4” = Video is selected
“5” = S-video is selected

Unacceptable “?”

[CR]

7.6. Lamp Time Read Command

Command “CR3”

[CR]

Detail

Get the total lamp running hours (Not actual lamp used hour, but Eco mode
corresponding value).

Response

Acceptable “%1”

[CR]

%1

Shows the time period with 5 digits numbers.
Example: “00410”[CR] ・・・・shows 410 hours

Unacceptable

“?”

[CR]

7.7. Setting Read Command

Command “CR4”

[CR]

Detail

Get screen setting status such as Ceiling / Rear.

Response

Acceptable “%1”

[CR]

%1

“11”[CR] = Normal Screen Setting
“10”[CR] = Picture is top/bottom reversed.

(Status: Rear&Ceiling ON)

“01”[CR] = Picture is left/right reversed. (Status: Rear ON)
“00”[CR] = Picture is top/bottom and left/right reversed.

(Status: Ceiling ON

)

Unacceptable “?”

[CR]

7.8. Temp Read Command

Command “CR6”

[CR]

Detail

Get the temperature data inside the projector.
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.

Response

Acceptable “%1_%2_%3”

[CR]

%1
%2
%3

%1=Temperature of sensor 1
%2=Temperature of sensor 2
%3=Temperature of sensor 3
Temperature data is shown as “00.0”.
When the temperature goes down to -, the first character
becomes “-” instead of a space, like “-05.5” [CR].
When no temperature data can be returned due to hardware
problems, the first character becomes “E” like”E00.0” [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
“_31.5 _ _35.2 _ _33.4”[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.

Unacceptable “?”[CR]