2. Notes for Using the Instrument

Digital camera

• The digital camera installed on the Digital Retinal Camera CX-1 is designed for the CX-1.
• The specifications differ from the typical commercially-available Canon digital cameras. Use only for

observing and taking photographs of peoples’ eyes. Do not detach the digital camera from the main unit
to use separately or failure of the instrument may result.

• If any problems with the digital camera occur or repairs are needed, please contact your sales

representative or local Canon dealer.

Before use

• Take a daily test image to ensure that there is no foreign matter present that can affect image readings.
• Check and clean the objective lens before taking an image, as any stains or scratches on it will appear

as white spots.

• Sudden heating of the room in cold areas will cause condensation to form on the objective lens or on

optical parts inside the instrument. In this case, wait until condensation disappears before performing
photography.

• Do not touch the lens of the retinal camera or the mirror of the digital camera when attaching and

detaching the digital camera from the retinal camera body. If any dirt, fingerprints, dust, or other foreign
objects attaches to the lens or mirror part, you will not be able to take a good image.

• Be sure to adjust the diopter of the viewfinder to match the diopter of the photographer’s eye. Otherwise,

focusing will not be able to be performed correctly.

After use

• Turn OFF the power of the instrument. Place the cap over the objective lens, and place the dust cover

over the instrument. You will not be able to take a good picture when the objective lens is dirty.

• If the digital camera is removed and left unattached, dust and other foreign objects can enter the retinal

camera and the digital camera. Be sure to always attach the caps to the respective mounts.

Cleaning and disinfection

• Do not let the tip of a blower touch the objective lens.
• Do not wipe off or rub the objective lens when there is dust or other substances on it.

This could scratch the lens surface.

• Never wipe the objective lens with disinfecting ethanol, eyeglass lens cleaner, or cleaning paper

containing silicon. The lens surface could be damaged or the surface may not be completely wiped off.

• Do not clean the cover of the instrument with lens cleaner. The cover of the instrument could be

damaged.

• Never use alcohol, benzine, thinner, or other solvents to clean the cover of the instrument. This could

damage the cover of the instrument.