30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

Four Conductor Wire Connection to Range
(mobile homes)

1. Remove the 3 screws at the lower end of the rear

wire cover, then raise the lower end of the rear
wire cover (access cover) upward to expose range
terminal connection block (see Figure 2).

2. Remove the grounding strap from the terminal block

and from the appliance frame.

3. Using the nuts supplied with the literature package,

connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure 4).

4. Connect the neutral of the copper power supply

cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal).

5. Lower the terminal cover and replace the 3 screws.

Cord

Mounting

Plate

A

supplied by the

must be installed at

this location

strainrelief

user

Terminal

Block

To 240 V

receptacle

White Wire

(Neutral)

Grounding

Strap

Black

wire

Red wire

Silver colored Terminal

1-1/8“ Dia.

Direct

Connection

Hole. Punch

out knockout

for 1-3/8“ Dia.

Cord Kit Hole

3

Electrical Connection to the

Range (U.S.A.)

This appliance is manufactured with the neutral terminal

connected to the frame.
Note: Refer to the wiring diagram in the center pages of

this manual.

Three Conductor Wire Connection to Range

(The 3-conductor cord or cable must be replaced with

a 4-conductor cord or cable where grounding through

the neutral conductor is prohibited in new installations,

mobile homes, recreational vehicles or in other areas

where local codes do not permit neutral grounding)

If local codes permit connection of the frame grounding

conductor to the neutral wire of the copper power

supply cord (see Figure 3):

1. Remove the 3 screws at the lower end of the rear

wire cover, then bend the lower end of the rear

wire cover (access cover) upward to expose range

terminal connection block (Figure 2).

Figure 3

Figure 2

BEND REAR WIRE COVER HERE

FOR ACCESS TO TERMINAL BLOCK

2. Using the nuts supplied in the literature package,

connect the neutral white wire of the copper power

supply cord to the center silver-colored terminal of

the terminal block, and connect the other wires to

the outer terminals. Match wires and terminals by

color (red wires connected to the right terminal,

black wires connected to the left terminal).

3. Lower the terminal cover and replace the 3 screws.