Electrolux EI30DS55JS User Manual

Page 9

Advertising
background image

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

9

All connections must be wrench-tightened

Figure 10

Flare

Union

Flare

Union

GAS FLOW

Manual

Shutoff

Valve

Pressure

Regulator

On

Off

Flexible

Connector

Access

Cap

Nipple

Nipple

Shutoff Valve -

Open position

to appliance

to gas suppl

y line

Figure 11

PRESSURE REGULATOR

LOCATION

Figure 9

Connection to Pressure Regulator

The regulator is already installed on the appliance.

Do not make the connection too tight.

The regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible fire or
explosion.

Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
1. manual shutoff valve (not supplied)
2. 1/2" nipple (not supplied)
3. 1/2" flare union adapter (not supplied)
4. flexible connector (not supplied)
5. 1/2" flare union adapter (not supplied)
6. 1/2" nipple (not supplied)
7. pressure regulator (supplied)

The gas supply line to the shutoff valve should be
1/2"(1,27 cm) or 3/4"(1.9 cm) solid pipe.

The user must know the location of the main shutoff
valve and have easy access to it.

When using flexible gas conduit on the range, allow
sufficient slack to pull the range outside the cutout for
cleaning or servicing.

NOTE: Do not allow the flexible conduit to get pinched
between the wall and the range. To visually check,
remove the range drawer.

Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not
kinked.

The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in
the same room as the range and should be in a location
that allows ease of opening and closing. Do not block
access to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance.

Once regulator is in place, open the shutoff valve in the
gas supply line. Wait a few minutes for gas to move
through the gas line.

Leak testing of the appliance shall be conducted
according to the manufacturer's instructions.

Check for leaks. After connecting the range to the gas
supply, check the system for leaks with a manometer. If
a manometer is not available, turn on the gas supply and
use a liquid leak detector at all joints and connections to
check for leaks.

Do not use a flame to check for leaks

from gas connections. Checking for leaks with a flame
may result in a fire or explosion.

All openings in the wall or floor where the range is to be
installed must be sealed.

Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.

Disconnect this range and its individual shutoff
valve
from the gas supply piping system during any
pressure testing of the system at test pressures greater
than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).

Isolate the range from the gas supply piping system
by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa or
14"(35,56 cm) water column).

Advertising