• Turn lightly the cable to make the

connection easier later.

• be careful not to let the drain hose

become slack.

• Heat insulate the connecting pipe.
• be sure that the drain hose is located at

the lowest side of the buddle. Locating

at the upper side can cause drain pan to

overflow inside unit.

• Never cross connect or interwind the

power wire with any other wiring.

• Do not allow the piping to be exposed

out from the back of the indoor unit.

• If part of the drain hose is positioned

inside the room, wrap it with insulating

materials so as to prevent condensed

water from dropping.

• Connect the indoor unit first, then the

outdoor unit.

• Do not plug the cable to the indoor unit.

That must be done later.

Fixing lower hook

• Do not route both refrigerant piping and

drain hose from the right side to the left

side to prevent big gap between the

indoor unit and the wall.

Drain hose

from the right side

Piping and cable

from the right side

4 Take out the piping from body case, wrap

the piping, power cords, drain hose with the

tape and then make them pass through the

piping hose.
Do not put any object in the drain pan

located in the rear of the indoor unit, as the

condensed water is gathered there and

piped out of the room.

5 Hang the mounting slots of the indoor unit on

the upper hooks of the mounting plate and

check if it is firm enough .
To ease the piping installation, put a spacer

between the indoor unit and the wall.
Remove the spacer once finished.

indoor Unit

Piping

insulation

Upper hook

Mounting

plate

Spacer

Liquid pipe

Gas pipe

Connecting

cable

6 Press the lower left and right sides of the unit

against the mounting plate until the lower

hooks engage into their slots.
Ensure the unit is firmly fitted.

Drain hose

Drain hose

Mounting plate

7 The installation site should be 2.5 meters or

more above the floor.

caution

Upper hook

Connecting

cable