installation site instruction

More than 30cm

More than 30cm

More than 2m

More than 50cm

More than 15cm (ceiling)

More than

15cm

More than

15cm

More than 2m (floor)

Less than 2.5m (floor)

7 Select place about 1m or more away from a

TV set or any other electric appliance.

8 Select a place where the filter can be easily

taken out.

9 Do not use the unit in the laundry or by

swimming pool etc.

10 A minimum pipe run of 3 meters is required to

minimize vibration and noise.

11 Use a stud finder to locate studs to prevent

unnecessary damage to the wall.

12 Any variations in pipe length will/may require

adjustment to refrigerant charge.

13 Do not install near a door way.

Outoor Unit

1 Select a site where noise and outflow air

emitted by unit will not annoy neighbors.

2 Select a site where there is sufficient

ventilation.

3 Select a site where there is no obstruction

blocking the inlet and outlet.

4 The site should be able to withstand the full

weight and vibration of the unit.

5 Select a dry place, but do not expose the unit

to direct sunlight or strong wind.

6 Make sure that the outdoor unit is installed in

accordance with the installation instructions,

and is convenient for maintenance and repair.

7 Select a place where it is out of reach of

children and far from animals or plants.

8 Select a place where the unit keeps the

horizontal and aligned position.

9 Select at a place that respects the minimum

distances around the outdoor unit as below:

A proper installation site is vital for correct and

efficient operation of the unit.
Avoid the following sites where:
• strong heat sources, vapour, flammable gas

or volatile liquids are emitted.

• high-frequency electro-magnetic waves are

generated by radio equipment, welders or

medical equipment.

• salt-laden air prevails (such as close to

coastal areas).

• the air is contaminated with industrial vapours

and oils.

• the air contains sulphurous gas such as in hot

spring zones.

• corrosion or poor air quality exists.

indoor Unit

1 The air inlet and outlet should be away from

the obstructions. Ensure the air can be blown

through the whole room.

2 Select a site where the condensing water can

be easily drained out, and where it is easily

connected for the outdoor unit.

3 Select a place where it is out of reach of

children.

4 Select the place where the wall is strong

enough to withstand the full weight and

vibration of the unit.

5 be sure to leave enough space to allow

access for routine maintenance.
For optimum performance, the indoor unit

should be installed on the wall at a height

no less than 2.5 meters above the floor.

6 Make sure that the indoor unit is installed in

accordance with installation dimension as

below: