Comfort cool installation manual - l1_ 10, Indoor, Outdoor – Electrolux EXI09HD1WI User Manual

Page 10

Advertising
background image

10

Outlet pipe of
indoor unit

Vinyl tape

Outlet pipe of
indoor unit

Drain hose

Outlet pipe of
indoor unit

Drain hose (narrow)

Vinyl tape Insulating pipe

Indoor

Wall pipe

Seal putty

Outdoor

Ø55
or Ø70

5-10mm

Wall

Mounting Plate Type E

Step 2: Drill Piping Hole

1 Determine hole positions according to the

GLDJUDP'ULOORQH  KROH ɎRUɎPP 
in the wall at a slight downward slant to the
outdoor side.

Piping hole

Model

ɎPP

Cooling capacity <6000W

ɎPP

Cooling capacity >6000W

2 The inclination must be between 5 - 10mm in

order to ensure a good drain of condensed
water generated by the indoor unit.

Step 3: Installation of Drain Hose

Remove both supports

3 Insert the wall pipe into the hole to prevent

and wiring from being damaged when passing
through the whole.

4 Always use a wall hole conduit when drilling

metal grids, metal plates or the like.

5 For cooling capacity over 4500W models,

remove and dispose the two polystyrene lateral
rear supports from the indoor unit before the
installation.

1 Connect the drain hose to the outlet pipe of the

indoor unit. Bind the joint with vinyl tape.

2 Put the drain hose into insulating pipe.

186.5

260.5