Anti-cold air function

In HEAT mode, the indoor fan will not

operate in order to prevent cold air from

blowing out if the indoor heat exchanger

does not reach a certain temperature in

one of the following situations:
• when the heating operation starts;
• when the defrosting operation is

finished;

• when heating at low temperature.

Gentle breeze

The indoor unit may blow gentle breeze

and the horizontal louvre rotates to a

certain position in one of the following

situations:
• In HEAT mode, the compressor does

not start operation after switching on

the unit.

• In HEAT mode, the temperature

reaches the set value and the

compressor has stopped operation

for 1 minute.

Opetaring temperature range

The operating temperature range for

cooling-only units is 16-48˚C. The

operating temperature range for heat-

pump units is -20-(+24)˚C.

Tip for energy saving

• Do not overcool or overheat. Setting

the temperature at a moderate level

helps energy saving.

• Cover windows with a blind or a

curtain. Blocking sunlight and air from

outdoor is favorable for cooling.

• Clean air filters every two weeks.

Clogged air filters lead to inefficient

operation and energy waste.

Tip for relative humidity

• If the unit is operated in an area with

a relative humidity of more than 80%

for a long time, condensate may drip

from the indoor unit.

Installation notes

• Not following the instructions can

cause personal injury and/or property

damage.

• Not following the instructions can

cause the unit to fail.

• Let the unit be installed by an

authorised service centre.

• Let the unit be installed in compliance

with local and governmental

regulations.

• Let the unit be installed according to

the instructions from this manual.

• First contact an authorised service

centre before relocating an already

installed unit

• Disconnect power before working on

the unit.

• Let the mains cable be repaired by an

authorised service centre or qualified

technician for units with Y-attachment.

• The mains plug must remain

accessible after installation.

• Keep sufficient distance between

the interconnection cable and the

Indoor side (°C)

Outdoor side (°C)

Max. cooling

32

48

Min. cooling

21

16

Max. heating

27

24

Min. heating

20

-20