5.2 Defrosting the refrigerator

Frost is automatically eliminated from the
evaporator of the refrigerator compart-
ment every time the motor compressor
stops, during normal use. The defrost wa-
ter drains out through a drain hole into a
special container at the back of the appli-
ance, over the motor compressor, where
it evaporates.
It is important to periodically clean the de-
frost water drain hole in the middle of the
refrigerator compartment channel to pre-
vent the water overflowing and dripping
onto the food inside.

5.3 Defrosting of the freezer

The freezer compartment of this model,
on the other hand, is a "no frost" type.
This means that there is no buildup of
frost when it is in operation, neither on the
internal walls nor on the foods.
The absence of frost is due to the contin-
uous circulation of cold air inside the
compartment, driven by an automatically
controlled fan.

5.4 Periods of non-operation

When the appliance is not in use for long
periods, take the following precautions:
disconnect the appliance from elec-

tricity supply

• remove all food

• defrost (if foreseen) and clean the appli-

ance and all accessories

• leave the door/doors ajar to prevent un-

pleasant smells.

If the cabinet will be kept on, ask some-
body to check it once in a while to pre-
vent the food inside from spoiling in case
of a power failure.

5.5 Replacing the carbon air
filter

To get the best performance the carbon
air filter should be changed once every six
months.
New active air filters can be purchased
from your local dealer.
Refer to "Installation of the carbon air fil-
ter" for the instructions.

6. WHAT TO DO IF…

WARNING!
Before troubleshooting, discon-
nect the mains plug from the
mains socket.
Only a qualified electrician or com-
petent person must do the trou-
bleshooting that is not in this man-
ual.

There are some sounds during
normal use (compressor, refriger-
ant circulation).

Problem

Possible cause

Solution

The appliance does
not operate. The
lamp does not oper-
ate.

The appliance is switched
off.

Switch on the appliance.