DATA BIT

FUNCTION OF BIT

IF IT IS A "0"

IF IT IS A "1"

0

Pulse Rate Source Selection

Base Speed

Max Speed

1

Ramping Up/Down Enable

No Ramping

Ramping

2

Pulse Direction Selection

CW

CCW

3

STOP

No Function

Stop

4

START

No Function

Start

5

No Function

No Function

No Function

6

MUST BE A ZERO

Always

Not Allowed

7

MUST BE A ZERO

Always

Not Allowed

START STOP COMMAND INDIVIDUAL BIT DEFINITIONS

INITIAL SETUP COMMANDS
To set up the Position Register and Encoder Register, set the following

send to the Command Buffer Register:

136

send to the LSB

1

send to the MID

144

send to the MSB

0

Another set up that should be sent to the board initially and after any 'Origin Index with the encoder Z channel'.

send to the Command Buffer Register:

65

INPUT AND OUTPUT CONTROL COMMANDS

This set of commands primarily affects the enabling and disabling of the limit switches. To enable a limit switch, select
a "1" for that Data Bit. To disable a limit switch, select a "0" for that Data Bit. Enabling and Disabling the Limit Switches
does not affect the reading of those switches.

DATA BIT

FUNCTION OF THE BIT

IF IT IS A "0"

IF IT IS A "1"

0

Must be a 0

Always

Not Allowed

1

±SOFT Signal Input Enable

Not Enabled

Enabled

2

EZ Signal Input Enable

Not Enabled

Enabled

3

HOME Signal Input Enable

Not Enabled

Enabled

4

No Function

No Function

No Function

5

Must be a 1

Not Allowed

Always

6

Must be a 1

Not Allowed

Always

7

Must be a 1

Not Allowed

Always

INPUT AND OUTPUT CONTROL COMMANDS

LIST OF EQUATIONS