Introduction, Revision history, Trademark information – ADC FPL Series User Manual

Page 2: 1 description, Description, 1description

Advertising
background image

ADCP-90-328 • Issue 2 • November 2005

Page 2
© 2005, ADC Telecommunications, Inc.

5.6

Installing FOT Patch Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

5.6.1

Interconnect Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

5.6.2

Cross-Connect Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

6

OPERATION (CROSS-CONNECT PATCH CORDS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

7

CUSTOMER INFORMATION AND ASSISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

APPENDIX A: SHIELD CONNECTOR INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

_________________________________________________________________________________________________________

INTRODUCTION

This user manual describes the FPL Series Termination/Splice Panel, and provides all
information required to install and operate this product. All FPL panels can be mounted on
either a 19-inch or 23-inch WECO or EIA rack.

Revision History

quad cables and patch cord routing

Trademark Information

ADC is a registered trademark of ADC Telecommunications, Inc.

1

DESCRIPTION

The FPL Series Termination/Splice Panel documented in this manual may be any of a number
of rack-mounted panels built using the same chassis style and incorporating similar features
such as angled adapters and vertical cable guides. Panel configurations include the following:

Termination Only Panels—Available with 12, 24, 48, 72, or 96 termination positions.

LX.5 and LC connectors may be used with the 12, 24, 48, and 72 position panels to double
the density. These panels require connectorized fibers on both sides of the termination
bulkhead.

Termination and Splice Panels—Available with 12, 24, 48, 72, or 96 termination

positions. LX.5 and LC connectors may be used with the 12, 24, 48, and 72 position
panels to double the density. These panels provide a transition between bare fibers and
connectorized fibers.

• High Density Termination and Splice Panel—Provides 144 termination and splice

positions in the same chassis, using standard connector types. The bulkhead on this panel
is slanted inward in a “V” design to provide room for a greater number of adapters.

Content (continued)

Page

ISSUE

DATE

REASON FOR CHANGE

Issue 1

07/2002

Original.

Issue 2

11/2005

Added 1RU 12/24 position panels.