Nilfisk-ALTO BK 2.0 User Manual

Page 8

Advertising
background image

7

2.Close LED

This LED illuminates when expansion occurs.

4

5

6

8

7

9

3

10

Pic.3: Controls of the Compressor/Limiter section

COMPRESSOR / LIMITER

THRESHOLD

RATIO

ATTACK

AUTO RELEASE

OUTPUT IN/OUT

dBu

n:1

ms

dB

EFFECT

IN

-40

+20

+10

-20

0

-10

1

LIM

1.5

8

2

5

2.5

0.1

200

1

150

10

100

50

50m

4

0.1

2

0.3

1

0.5

-20

+20

-14

+14

-6

+6

0

ENHANCER

PROCESS

OFF

6

1

5

2

4

3

30

20

15

10

6

4

2

1

CH1

CH2

AUTO CH1 IN

AUTO CH2 IN

GAIN REDUCTION (dB)

sec

3.2 Compressor Section

Engage this switch to activate the corresponding channel. It can be used to make an A/B comparison in be-
tween processed and unprocessed signal.

3. EFFECT Switch

4. THRESHOLD Control

This control adjusts the threshold level for the Compressor section in the range of -40dBu to +20dBu. The SKC
(Smart Knee Control) is applied to the audio signal, which is a maximum of 10dB above the set threshold.
Above such level (10dB) a hard knee compression will be applied.

5. Ratio Control

The ratio between the input and output level of audio signals exceeding the set threshold level is determined by this
control. This control is manually adjustable from 1:1 to LIM:1.

6.Attack Control

This control determines how fast the compressor is to respond to audio signals that will exceed the set threshold. It can be
manually adjusted from 0.1 to 200 milliseconds.

7. Release Control

This control determines how fast is the compressor to return to unity gain when the audio signal falls below the set
threshold level. It can be manually adjusted from 0.05 to 4 seconds.

8. Auto Switch

Who needs Attack and release control? Activate this switch and these controls will be deactivated. Attack and release
controls will be automatically set by the unit depending on the program material.

9.Output Gain Control

Through this control you can vary the output signal by a maximum of 20 dB. In this way you can recover a level
that had been lost because of the compression process.

10. Gain Reduction Meter

It indicated the gain reduction. The range displayed is 1 to 30 dB.

3.3 Dynamic Enhancer Section

11

Pic.4: Controls of the Dynamic Enhancer section

ENHANCER

PROCESS

OFF

6

1

5

2

4

3

Advertising