Warning – Bosch SHX65T55UC User Manual

Page 3

Advertising
background image

2

Avoiding General Hazards

Do not use the dishwasher until it is completely installed. When opening

the door on an uninstalled dishwasher, carefully open the door while

supporting the rear of the unit. Failure to follow this warning can cause the

dishwasher to tip over and result in serious injury.

Before installing the supplied counter top mounting brackets, decide which

method will be used to secure the dishwasher into its opening. Once these

mounting brackets are installed on the dishwasher, removing them is dif-

ficult and will damage the mounting brackets and the dishwasher.

In some conditions, hydrogen gas can form in a hot water system that

has not been used for weeks. Hydrogen gas is explosive. Before filling a

dishwasher from a system that has been off for weeks, run the water from

a nearby faucet in a well ventilated area until there is no sound or evidence

of gas.

Temperatures required for soldering and sweating will damage the dish-

washer’s base and water inlet valve. If plumbing lines are to be soldered

or sweated, keep the heat source at least 6″ (152.4 mm) away from the

dishwasher.

Removing any cover or pulling the dishwasher from the cabinet can

expose hot water connections, electrical power and sharp edges or points.

Handle with care.

Avoiding Electrical Shock/Fire Hazards

Do not work on an energized circuit. Doing so could result in serious

injury or death. Only qualified electricians should perform electrical work.

Do not attempt any work on the dishwasher electric supply circuit until

you are certain the circuit is de-energized.

Make sure electrical work is properly installed. There should be no loose

electrical connections. Ensure all electrical connections are properly

made.

The customer has the responsibility of ensuring that the dishwasher

electrical installation is in compliance with all national and local electrical

codes and ordinances. The dishwasher is designed for an electrical

supply of 120V, 60 Hz, AC, connected to a dishwasher-dedicated, properly

grounded electrical circuit with a fuse or breaker rated for 15 amps.

Electrical supply conductors shall be a minimum #14 AWG copper only

wire rated at 75°C (167°F) or higher.