Al7024s quick start manual – Altech Auto Security AL7024S User Manual

Page 17

Advertising
background image

AL7024S Quick Start Manual

No. AL7020S-QSM-101

Altec Electronic AG

Seite 17 / 18

Ringing

To test this, call first to a normal telephone and look, if it is ringing. (

ATDxxx;

with

semicolon for speech-mode). Call also from telephone to GSM.

(Response

RING

or

INCOMING SPEECH CALL

)


(This is to see, if the GSM-network connects, or if it is a problem with numbering of
house-exchange, or bad configured ISDN-phones)

Make speech-connection to phone

Do the same and pick the phone up, the GSM should show "

CONNECT (SPEECH)

". In

the other direction, wait the GSM-module indicating the ring and enter "

ATA

". Now a

CONNECT

should show up. At this step you can also test a headset connected to the

GSM-Module.

Configure both sides for data-transmission:

- Set

ATS0=2

at both sides, so calls are answered after 2 rings.

- Set

AT+CSNS=4

/

AT+FCLASS=0

at GSM Modem (data mode), specially if you want

to receive call with GSM.


- Set data-protocol:

- GSM to ISDN-TA:

AT+CBST=71,0,1

(9600 V.110) . Other TA must be set to


V.110 (9600 or higher), other protocols don't work.

- GSM to Analog-Modem:

AT+CBST=7,0,1

(V.32 9600 baud) (ev. set analog-modem

accordingly).

After the settings, save them with

AT&W

.


If the other side is an ISDN-TA, this needs an MSN-number to be stored. You could
disconnect the ISDN-phone used in step above and set the TA to the same MSN as
the phone.

Advertising