Specifications, Setup – Water Inc HOUSEPURE HP04 User Manual

Page 5

Advertising
background image

Specifications

Feedwater
! Do not use this system on water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system. !
Minimum inlet pressure: 40 psig
Maximum outlet pressure: 125 psig


Power
Voltage: 120VAC
Frequency: 60Hz
Power consumption: 7 Watts Maximum

Installation

Minimum ambient temperature: 34 degrees F
Maximum ambient temperature: 122 degrees F

Setup

Unpacking and Inspection
Check the system components for damage or missing parts.


Where to Install the Filter
Consider the following points when determining where to install the water filter:
• Place the system as close as possible to a sewer drain. Runs of up to 12’

elevation above the control head is permissible.

• Do not install the filter where it would block access to the water heater, or

access to the main water shutoff, water meter, or electrical panels.

• A 120V electrical outlet is needed to plug in the transformer. If the outlet is

remote (up to 100 feet), use 18 gauge wire to connect.

• Always connect the system to the main water supply pipe before the water

heater.

• Install the system where it will not be subject to temperatures outside of the

limits stated in the Specification section or to direct sunlight.