Option B: replace the whole cartridge

• Remove the cover (Caution: the mist outlet is loose!).

Remove the water tank from the base and unscrew the

water tank cap (17).

• The demineralization cartridge is attached to the inside

of the tank cap. Unscrew the cartridge from the cap by

turning it counter­clockwise (18). Important: do NOT

dispose of the water tank cap!

• Throw the whole cartridge into the waste (21).

• Unpack the new cartridge (23).

• Screw the cartridge on the water tank cap (25). Close

tank cap well, place the tank on the lower part and

insert mist outlet (26).

• Soak the new cartridge for 24h before use! The resin

must soak up water to reach full performance!

Cut the bag open at the marked point.