Agilent Technologies J3972A User Manual

Page 48

Advertising
background image

Local Terminal Configuration
Using a Local Terminal

28

It requires the IP Address, Subnet Mask, and Default
Gateway IP Address fields. The following apply to Telemetry
ports:

z

HP OpenView can discover the interface

z

The interface is IP addressable

z

The interface responds to RMON-1

z

The interface will transmit all traps from the probe

z

The interface will transmit all extended RMON packets

sample from Monitor-only ports, Monitor/Transmit ports.

IP Address

Press

3

and enter the IP address for the probe. If the IP

address is

0.0.0.0

, the probe will transmit Bootp Requests

for configuration information (including IP address) over the
network. This does not apply to ports configured as Monitor-
Only.

Default Gateway

Press

4

and enter the default gateway IP address for the probe

IP Address

(optional).

Subnet Mask

Press

5

and enter the subnet mask for the probe.

Physical

Press

6

and select the physical connector. The menu only

Connector

shows the physical connectors that are available. You can use
the RJ-45 or AUI connector. If you select AUI, items 7 and 8
(Link Speed and Full/Half Duplex) are not available. AUI is
10MB/s half-duplex.

CAUTION

If you manually selected the Link Speed, be careful to configure it correctly. If
you configure the Link Speed for 100 MB/s and you connect the probe to a
10MB/s network, the probe will generate 100% utilization for that segment.

Link Speed

Press

7

and select the Link Speed as Auto Negotiate,

10MB/s, or 100MB/s. When you configure this parameter for
Auto Negotiate, the item 8 parameter (Full/Half Duplex) is
not available.