Agilent Technologies J3972A User Manual

Page 59

Advertising
background image

Local Terminal Configuration

Using a Local Terminal

39

Serial port speed

Press

5

and then enter a serial port speed (300 to 38,400

baud) for the probe’s SNMP connection. The default is
9600 baud. This speed is used only for Out-of-Band
access to the probe using SNMP. It does not affect the
serial connection for the local terminal, which is fixed at
9600 baud.

Make sure that the serial port speed is set to less than or
equal to the maximum speed of the modem to be used.

Serial port mode

Press

6

and then select the serial port mode by pressing

1

for direct connection (the default) or

2

for modem

connection.

Serial port hardware

Press

7

and then select hardware flow control Off by

flow control

pressing

1

or hardware flow control On (the default) by

pressing

2

.

Modem Init String

Press

8

to enter the modem initialization string. Only the

first 20 characters of the 256 character maximum will be
displayed in the Modify/View Serial Port Settings menu.
The default is

^s^M^d1^sATEOQOV1X4 S0=1

S2=43^M

.

Modem Hangup

Press

9

to enter the modem hang-up string. Only the

String

first 20 characters of the 256 character maximum will be
displayed in the Modify/View Serial Port Settings menu.
The default is

^d2^s+++^d2^sATHO^M^d2

.

Modem Connect

Press

10

to enter the modem connect responses. Only

Responses

the first 20 characters of the 256 character maximum will
be displayed in the Modify/View Serial Port Settings
menu. The default is

/CONNECT/300/CONNECT

1200/1200/CONNECT 2400/2400/CONNECT

4800/4800/CONNECT 9600/9600/CONNECT

14400/14400/CONNECT 19200/19200/

CONNECT 38400/38400/

.