Restarting the Probe

97

Selecting the Cold Start Menu Item

Use the following procedure to cold start the probe using the probe’s Main Menu:

1. Connect a local terminal (or a PC emulation a terminal) to the probe. Refer

to “Probe Operation” on page 91 for information on connecting a local
terminal.

2. Press the CONFIG button once (on the back of the probe) to place the probe

into the configuration mode. Use a narrow, pointed object (like a pen) to
press the recessed CONFIG button. The probe then displays its Main Menu
on the terminal. Figure 5-1 on page 95 shows the probe’s Main Menu.

3. Press

8

to execute a cold start and to exit the probe’s Main Menu. The cold

start occurs immediately. The Activity and Fault LEDs are turned on during
a cold start. When the cold start completes, the Activity LED flashes to
indicate traffic (if present), the Fault LED turns off, and the ~Line On (or
Power) LED is on.