Local Terminal Configuration
Using a Local Terminal

30

Figure 2-6: Modify/View Interface Values Menu (Token-Ring)

2. Select each field requiring configuration (one at a time) by pressing its

corresponding number and then entering the values that are appropriate for
your network.

Port Press

1

and then press the number of the Token-Ring port to

display the Token-Ring port’s configuration parameters along
with their current settings. The port number for the
Token-Ring interface (if installed) depends on where it is
installed. Refer to “Display Interface Summary” on page 36
for information on port types and port numbers for the
installed interfaces. You can then view or configure the
Token-Ring port’s configuration parameters.

Modify/View Interface Values Menu - Firmware Rev

MAC Address

00 00 C6 XX XX XX

Interface Type

Token Ring

1. Port

3

2. Port Type

Telemetry

3. IP address

0.0.0.0

4. Default gateway IP address

0.0.0.0

5. Subnet mask

0.0.0.0

6. Token-Ring Speed (Mbps)

16

7. Ring Number

-1

S. Save changes and exit

0. Cancel changes and exit