Installation

Connecting the Probe

63

4. Connect power to the modem and turn on the modem power switch (not

required for a PC internal modem).

5. Perform any other instructions as required by the modem manufacturer. If

you have any problems with the modem, contact the modem manufacturer
for assistance.

Install the Probe’s Modem

You need the following list of equipment to install the probe’s modem:

z

Hayes-compatible 300 to 38.4 K baud modem

z

RS-232C (straight through) modem cable

z

Modular phone cable with RJ-11 connectors or equivalent

Use the following procedure to install the probe’s modem:

1. Place the modem close enough to the probe to not violate the 50-foot

RS-232C distance limitation.

2. Connect an RS-232C cable from the modem’s RS-232C port to the probe’s

RS-232 port. A null modem cable cannot be used for this connection.

3. Connect the RJ-11 modular phone cable from the modem To Line port to

the telephone jack.

4. Connect power to the modem and place the modem power switch to on.

5. Perform any other instructions as required by the modem manufacturer. If

you have any problems with the modem, contact the modem manufacturer
for assistance.

Configure the Management Station and the Probe

Refer to your NetMetrix documentation for information on configuring the
management station for use with a modem. Verify that the packet retransmission
timeout is set appropriately. For example, a 1500-byte SNMP packet requires
about one second to transmit over a 9600 baud connection, with another one
second for the reply. A packet retransmission timeout of three to five seconds is
appropriate for this example.