3. Known Constraints

2.

When the DS3 interface is not connected, a trunk under this DS3 interface can appear
in either LOF or AIS alarm state.

Product

MP-11x

MP-124

Mediant 600

Mediant

1000

Mediant 800 MSBG

Mediant

1000

MSBG

Mediant 2000

Mediant 3000/TP-6310

Mediant

3000

HA/TP-6310

Mediant 3000/TP-8410

Mediant

3000

HA/TP-8410

3.

The DS3 External clock is not relevant for Asynchronous mapping of DS3 in OC3.

Product

MP-11x

MP-124

Mediant 600

Mediant

1000

Mediant 800 MSBG

Mediant

1000

MSBG

Mediant 2000

Mediant 3000/TP-6310

Mediant

3000

HA/TP-6310

Mediant 3000/TP-8410

Mediant

3000

HA/TP-8410

3.3.2

SDH Constraints

This release includes the following known SDH constraints:

1.

TU-11 Byte Synchronous mapping is not supported.

Product

MP-11x

MP-124

Mediant 600

Mediant

1000

Mediant 800 MSBG

Mediant

1000

MSBG

Mediant 2000

Mediant 3000/TP-6310

Mediant

3000

HA/TP-6310

Mediant 3000/TP-8410

Mediant

3000

HA/TP-8410

2.

For SDH/SONET and DS3 interfaces, if a trunk was in LOF alarm and the alarm was
then cleared, the trunk tends to revert to the RAI alarm for a short period before
moving to “no alarm” state.

Product

MP-11x

MP-124

Mediant 600

Mediant

1000

Mediant 800 MSBG

Mediant

1000

MSBG

Mediant 2000