Wiring tables – Aube Technologies TH146-P-2H1C User Manual

Page 4

Advertising
background image

TH146-P-2H1C

400-280-014-A 5/23/07 4/11

Wiring Tables

Heat Pump

Terminal

Device

1H1C

2H1C

TH

Console

Connect the console between the TH terminals (no polarity)

TH

PS

Plenum sensor

Connect the plenum sensor between the PS and CS terminals (no polarity)

CS

Common S

Common terminal for the plenum sensor and the outdoor sensor

OS

Outdoor sensor

Connect the outdoor sensor between the CS and OS terminals (no polarity)

DE

Dual Energy

Connect the dual-register meter between the DE and CC terminals (no polarity)

CC

Common C

Common terminal for the dual-energy meter and the unoccupied mode input

UN

Unoccupied mode input

Connect a dry contact between the UN and CC terminals (no polarity)

H

Humidifier (24 Vac / 1 A)

Connect the humidifier between the H terminals (dry contact)

H

R

Power (24 Vac)

C

Y

Compressor (24 Vac / 1 A)

W

Auxiliary heat (24 Vac / 1 A)

O/B

Reversing valve (24 Vac / 1 A)

G

Fan (24 Vac / 1A)

L

Fault (24 Vac / 5 mA)

WW

Defrost (24 Vac / 5 mA)

HVAC

Terminal

Device

1H

1C

1H1C

TH

Console

Connect the console sensor between the TH terminals (no polarity)

TH

PS

Plenum sensor

Connect the plenum sensor between the PS and CS terminals (no polarity)

CS

Common S

Common terminal for both plenum sensor and outdoor sensor

OS

Outdoor sensor

Connect the outdoor sensor between the OS and CS terminals (no polarity)

DE

Not used

CC

Common C

Common terminal for the unoccupied mode input

UN

Unoccupied mode input

Connect a dry contact between UN and R terminals (no polarity)

H

Humidifier (24 Vac / 1 A)

Connect the humidifier between the H terminals (dry contact)

H

R

Power (24 Vac)

C

Y

Cooling unit (24 Vac / 1 A)

W

Heating unit (24 Vac / 1 A)

O/B

Not used

G

Fan (24 Vac / 1 A)

L

Not used

WW

Not used

400-280-014-A (TH146-P-2H1C) ENG.fm Page 4 Wednesday, May 23, 2007 4:12 PM