General setting 5.1, Temperature setting 6.1, User’s guide – Aube Technologies TH146-P-2H1C User Manual

Page 9

Advertising
background image

TH146-P-2H1C

User’s Guide

Programmable H/C Controller

TH146-P-2H1C

400-280-014-A 5/23/07 9/11

n

Press Clk. The hour display flashes.

o

Set the hour using

.

p

Press Clk. The minute display flashes.

q

Set the minutes using

.

r

Press Clk. The day display flashes.

s

Set the day using

.

t

Press

to return to the normal display.

n

Press Clk for 3 seconds to display the year.

o

Set the year using

.

p

Press Clk to display the month.

q

Set the month using

.

r

Press Clk to display the date.

s

Set the date using

.

t

Press

to return to the normal display.

Press the Fan button to select the fan operating mode.

In automatic mode, the fan runs only when heating or cooling is
activated. NOTE: For gas-operated HVAC systems, there might
be a delay before the fan starts or stops when heating is acti-
vated or deactivated.

In continuous mode, the fan runs continuously and the

sym-

bol is displayed. NOTE: if Smart Fan is enabled, when the con-
troller is in periods 2 and 4 of automatic mode and in
unoccupied mode, the fan will run only when heating or cooling
is activated. The fan will run continuously the rest of the time

The controller normally displays the measured indoor temperature.
To view the setpoint, press one of the

buttons. The setpoint and

the symbol will be displayed for the next 5 seconds.

Press Mode to place the system in one of the following modes:

Time and day setting

Programming

Program day selection

Program clear

Humidity setting

Return

Temperature
adjustment
mode selection

Fan operating
mode selection

System operating
mode selection

Up/Down buttons

Indicator LEDs

FAULT

: System fault

EH

: Emergency heat mode

DE

: Dual energy

Day

Clock

Indoor temperature

Outdoor temperature

Indoor humidity

Indicator LEDs

Backlight

The screen is lit for 12 seconds
when any button is pressed.
However, the screen remains lit
while you are configuring the
controller.

5. General Setting

5.1

Clock and Day Setting

5.2

Date Setting

5.3

Fan Operating Mode

6. Temperature Setting

6.1

Display

6.2

System Operating Mode

HEAT

The system is in heating mode.

COOL

The system is in cooling mode.

AUTO

The system is in automatic changeover mode. (The system
switches between heating mode and cooling mode to main-
tain the desired temperature.)

OFF

The system is off.

EHEAT

The system is in emergency heat mode. Only auxiliary heat-
ing is used when there is a call for heat. (This mode applies
only when the controller is connected to a heat pump
equipped with auxiliary heating).

Heating is On

Cooling is On

System operating mode

Fan operating mode (ap-
pears when the fan is in
continuous mode, disap-
pears when it is in automat-
ic mode)

Temperature adjustment
mode (appears when the
system is in automatic
mode, disappears when it
is in manual mode)

Auxiliary heating is On

Appears when the
temperature setpoint
is displayed

Indoor temperature

400-280-014-A (TH146-P-2H1C) ENG.fm Page 9 Wednesday, May 23, 2007 4:12 PM