Hot Plugging

The Master View CS9134 / CS9138 supports hot plugging. Components can
be removed and added back into the installation by unplugging and replugging
their cables from their respective ports without the need to shut the switch
down. For hot plugging to work properly, the following procedures must be
observed:

Hot Plugging KVM Ports

When hot plugging cables from the KVM ports:

Š The cable must be plugged back into the same port it was removed from.
Š The mouse cable must be plugged in before the keyboard cable.
Š After plugging the cable back in, you must perform a KVM Reset on the

First Stage unit (by pressing the Reset switch In).

Hot Plugging Console Ports

The unit supports hot plugging of the keyboard, monitor, and mouse from its
console ports.

Note: 1. When hot plugging the mouse from the console mouse port (to reset

the mouse, for example), however, you must plug the same mouse
back in.

2. If, after hot plugging (or at any other time), there is no response to

mouse and/or PS/2 keyboard input, simultaneously press and hold
Port Select buttons 1 and 2 on the First Stage unit for 3 seconds to
perform a PS/2 Keyboard and PS/2 Mouse reset.

cs91348.book Page 15 Thursday, May 3, 2007 2:28 PM