Auto-config tab, Figure 3-16: auto-config tab 3-26 – Alvarion BREEZENET BU-DS.11 User Manual

Page 58

Advertising
background image

BreezeNET DS.11 Series User Manual

3-26

Send Trap Interval (sec): The time interval between two successive traps
when the number of transmitted broadcasts/multicasts exceeds the
permitted threshold.

The range is from 0 to 65535 seconds. 0 is for disabling traps sending.

The default is 300 seconds.

Auto-Config Tab

The Auto-Config tab enables quick configuration of various modes by setting
predefined values for several parameters upon clicking the applicable button.

Figure

3-16: Auto-Config Tab

Set PtP Mode: Click to set the following parameters to support optimized

configuration for Point-to-Point operation:

Minimum Contention Window = 15

RTS Threshold = 2437

Set PtMP Mode: Click to set the following parameters to support optimized

configuration for Point-to-Multi-Point operation with 2-5 RBs:

Minimum Contention Window = 63

RTS Threshold = 2437 in BU, 60 in RB

Advertising