background image

c.

Edit the DEPLOYSERVER.CMD file for your specific environment.

NOTE:

The IFHW and HWQUERY utilities can be used to assist in customizing the

DEPLOYSERVER.CMD script for your environment. For more information about these
utilities, see

“Toolkit utilities” (page 23)

.

The DEPLOYSERVER.CMD file is similar to the following:

rem @echo off

cls

echo [ SCRIPT FOR REMOTE INSTALL OF W2K3 ON TYPICAL SERVER ]

REM pause

echo Retrieving State Information...

%Tools%\System\statemgr /r phase

if errorlevel 3 goto State3

if errorlevel 2 goto State2

if errorlevel 1 goto State1

if errorlevel 0 goto State0

:State0

REM *** Configure the target server hardware by reading the

REM *** configuration information in the script file

echo Running Configuration Replication Utility...

%Tools%\System\conrep -l -f%GlobalData%\HardwareSettings\hwconfig.xml -x%Tools%\System\conrep.xml

echo Setting State Information...

%Tools%\System\statemgr /w Phase 1

:State1

REM===============================================================

REM *** Configure the array controllers by reading the

REM *** configuration information in the script file and stamping

REM *** it onto the array controllers of the target server

REM===============================================================

echo Configuring the Array Controllers...

%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 5i Controller"

if errorlevel 1 GOTO NEXT1

%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r0.ini

GOTO NEXT5

:NEXT1

%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 6i Controller"

if errorlevel 1 GOTO NEXT2

%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r1.ini

GOTO NEXT5

:NEXT2

%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 5312"

if errorlevel 1 GOTO NEXT3

%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r1.ini

GOTO NEXT5

:NEXT3

%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 640X Controller"

if errorlevel 1 GOTO NEXT4

%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r5.ini

GOTO NEXT5

16

Advanced topics

Advertising