HP Smart Update Manager (User Guide) User Manual

Page 36

Advertising
background image

Scripted deployment 36

Targets

Description

/oa_password

This argument provides the password credential for OA associated with VC specified

with "target" command-line parameter. Only one set of OA credentials can be
specified with command-line parameters. You can only add multiple VC targets to
command-line parameters with "target" parameter if the credentials of OAs associated

with specified VCs are the same. The argument oa_password is not required if VC has
the same credentials as the associated OA. You do not need to provide an OA network
address associated with Virtual Connect. HP SUM queries it from a specified VC target.

To update multiple VCs with different username and password or VCs with OAs which
have different credentials, the corresponding input files OAUID and OAPWD must be
used.

Log files

Description

/logdir "path"

This argument enables you to redirect the output from HP SUM or the HP BladeSystem

c-Class Onboard Administrator flash utility to a different directory than the default
location.

For Windows components, the default location is

%SYSTEMDRIVE%\CPQSYSTEM\hp\log<netAddress> and the redirected
location is <path>\hp\log\<netAddress>.

For Linux components, the default location is /var/hp/log/<netAddress> and the

redirected location is <path>/hp/log/<netAddress>.

/v[erbose] or

/veryv[erbose]

These arguments enable you to set the verbosity level for the HP SUM execution log file,
hpsum_execution_log_<date>_<time>.log. Using one of these arguments increases the

level of detail that is retained in the log file. The default value is normal verbosity.

Generating reports

Description

/report

This argument generates a report listing of the target summary and how the
components in the repository affect the target. For example, whether each component
applies to the target or not. The report is generated in HTML and XML with file name

formats of HPSUM_Report_<date>_<time>.html and
HPSUM_Report_<date>_<time>.xml.
By default, the files are located in the present working directory where HP Smart

Update Manager is initiated from. If that location is write-protected, the files can be
found in the same directory as the HP Smart Update Manager log files.

/inventory_report This argument generates a report listing of the components in the specified repository.

The report is generated in HTML and XML with file name formats of
HPSUM_Inventory_Report_<date>_<time>.html and
HPSUM_Inventory_Report_<date>_<time>.xml.

By default, the report is located in the present working directory from where HP SUM is
initiated. If that location is write-protected, the report can be found in the same
directory as the HP SUM log files.

/firmware_report This argument generates a report listing of the firmware installed and details of the

target. The report is generated in HTML and XML with file names of

HPSUM_Firmware_Report.html and fwreport.xml in the directory named
HPSUM_Firmware_Report_<date>_<time>.
By default, the report is located in the present working directory from where HP SUM is

initiated. If that location is write-protected, the report can be found in the same
directory as the HP SUM log files.

Advertising