Using this guide, New features of hp sum, Minimum requirements – HP Smart Update Manager (User Guide) User Manual

Page 7: Minimum requirements for windows servers

Advertising
background image

Introduction 7

Support for updating firmware on network-based targets such as the OA, iLO 2/iLO 3 through Network

Management Port, and VC Ethernet and Fibre Channel modules on HP ProLiant servers

NOTE:

HP SUM does not support third-party controllers. This includes flashing hard drives

behind these controllers.

Using this guide

HP SUM is included with many different deliverables. A deliverable is an HP product which contains HP SUM
and a set of firmware or software components, for example, the HP Smart Update Firmware DVD. Read your
deliverable’s overview section to verify specific HP SUM limitations, and then, review the SUM features

sections. For more information, see "Overview of supported deliverables ("

Supported deliverables overview

"

on page

10

)."

New features of HP SUM

HP SUM 5.0.0 includes support for:

New Graphical User Interface

Ability to deploy firmware from Windows servers to Linux targets

Support for Integrity BL8x0c i2, rx2800 i2, and Superdome 2 servers

Automatic discovery of blades and interconnects when given the Onboard Administrator as the target

Minimum requirements

Minimum requirements for Windows operating systems ("

Minimum requirements for Windows servers

"

on page

7

)

Minimum Requirements for Linux Servers ("

Minimum requirements for Linux x86 servers

" on page

8

)

The minimum display settings for optimum performance are 1024 x 768 pixels resolution.

NOTE:

For Windows operating systems, the respective device drivers for the embedded/add-on

devices in the target servers must be installed for HP SUM to discover the devices.

Minimum requirements for Windows servers

To successfully use HP SUM to deploy firmware and software to targets running a Windows® operating

system, the following must be available:

A local administrative system with 1 GB of memory

Sufficient hard-drive space of at least twice the file size of the components to be deployed

WMI enabled

All remote targets must be visible by the administrative system running HP SUM.

An account with administrator privileges on each target server
HP recommends that the user name and password for the administrator account on each target server
be the same as those on the local administrative system. If administrator privileges are not set up in this

Advertising