InstallSet.cpp[212]: Winnow--Adding FileName cp011500.exe

InstallSet.cpp[222]: Winnow--Removing FileName cp011504.exe

InstallSet.cpp[222]: Winnow--Removing FileName cp011505.exe

InstallSet.cpp[222]: Winnow--Removing FileName cp011550.exe

InstallSet.cpp[222]: Winnow--Removing FileName cp011560.exe

InstallSet.cpp[242]: Target 0: Added Bundle bp000648.xml

Recovering from a discovery failure

Troubleshooting connection errors

If you are receiving an HP SUM Connection Error or Discovery Failed messages, follow these
troubleshooting tips:

Ensure your workstation does not have an existing connection to the ADMIN$ share on the
target IP address. If the workstation does have a working connection, it prevents HP SUM from
connecting to the remote server share because the Windows operating system only allows
one connection from a client to a server share. This can be verified by entering net use at
a command prompt. If a share to the target IP address \admin$ share exists, delete it, and
then attempt the installation again.

Ensure that the target IP address server admin$ share is accessible. Validate the target server
can be accessed by entering net use x: \\<ip_address_or_dns_name>\admin$
for the target server IP address or DNS name. When the connection is validated, ensure that
it is deleted by entering net use x: /d at the command prompt.

Ensure that the user ID being used to connect to the target IP address server is part of the
administrator group or the Linux equivalent root group. If it is not, HP SUM blocks installation
to the target.

Ensure that WMI is enabled and running on all Windows target servers.

For Windows target servers, enter the user name in DOMAIN\USER format, where <user>
is the administrative user name, and <domain> is either the NETBIOS computer name or the
Active Directory domain name for this user account.

For Linux, ensure the SSH port is not blocked by the firewall. For more information, see

“Recovering from a loss of Linux remote functionality by configuring firewall settings” (page
31)

.

Ensure the firewall ports on any routers in the network as documented in the

“Enabling ports

in HP SUM” (page 33)

section of this document.

The SEP product blocks HP SUM ability to communicate with remote targets if the Network
Threat Analysis feature is enabled. Disable this feature while HP SUM is in use on the
workstation.

Examine the OpMan.trace, discagent.trace, and the discmanager.trace files to
determine the cause of the failure. For more information, see

“Collecting trace directories”

(page 28)

.

Ensure that the server has a valid serial number and product ID defined in the server BIOS.

HP SUM hangs during discovery

If a system hang is observed during HP SUM discovery and the system is connected to external
storage, in most cases disconnecting the external storage should resolve the issue.