Upgrading the firmware 41

Upgrading the firmware

Upgrading the console switch firmware

1.

Connect the serial cable to the serial port on the PC (must be running Microsoft® Windows®) and to
the serial port ("

Console switch components

" on page

11

) on the rear panel of the HP KVM Server

Console Switch G2.

2.

Go to the folder where the firmware files are saved and run the ApplianceUpDate.exe file.

NOTE:

The .bin files must be in the same folder as the ApplianceUpDate.exe file.

3.

Enter the COM port number being used to load the firmware.

4.

Click Load. The update process begins.
The update process has three updates—Loading Application Firmware, Loading Graphics Chip, and
Loading System Data. You see a progress bar for each of those three updates. The firmware update

is not done until all updates have been loaded. When the firmware is updated, the following

message, indicating "Update Complete" appears.

5.

Click Done.

Upgrading the interface adapter firmware

The Interface Adapter firmware can be loaded individually ("

Loading interface adapter firmware

individually

" on page

42

), or upgraded simultaneously ("

Upgrading interface adapter firmware

simultaneously

" on page

42

). The servers attached to the interface adapters must be powered on while

upgrading the firmware.