4.

Optional: Change the Maximum Number of Sharers (maximum number of logical servers
that will be allowed to share this storage pool entry), then click Update Maximum Sharers.

As logical servers share this storage entry, they are assigned one specific server WWN per
port.

5.

Optional: Check the Use Catalog Storage checkbox to display catalog storage options on
this screen (such as the Show Candidates button in the Volume & Path Definition table).
Check this checkbox if you preconfigured catalog storage using HP Storage Provisioning
Manager. See

“Setting up SPM for use with logical server storage” (page 63)

for more

information.

6.

Optional: Check the Request Binding checkbox to finalize the candidate selection configured
on this screen when the storage pool entry is saved. This checkbox is enabled only if Use
Catalog Storage

is checked.

Tag selections

The Tag List table allows you to select up to 16 storage tags for a storage pool entry.

1.

Select a storage tag from the drop-down menu. Your selection is highlighted.

2.

To create a storage tag, press the Manage Tags button on the Manage Storage Pool screen.
(Press Cancel on this screen to return to the Manage Storage Pool screen.)

Figure 4-12 Add storage pool entry definition and tag selection

Port definition

On the Storage Entry: SAN and Storage Pool Entry: SAN screens, the Port Selection table
allows you to define the ports that can be used to access the volume selections for this logical
server.

Any communication with SAN storage starts with the server’s Fibre Channel ports. Ports are
added in sequential order. For each port, you must select the fabric from a drop-down menu
with which the port will communicate. Each port is created with an automatically generated
server WWN assigned to it. This WWN, like a MAC address for NICs, is used to uniquely identify
this FC port to the SAN. The storage administrator provides access to these ports when
prepresenting LUNs.

Define one logical port for each server port (physical HBA port) by performing the following
steps.

1.

Click the Add Port button to add a row to the Port Selection table.

2.

Select a value from the Fabric drop-down menu.

The fabric corresponds to the Fibre Channel connection bay you want to use for
communication.

3.

Select a value from the Speed drop-down menu.

Logical server storage

73