Figure 12 – Allied Air Enterprises 4PGE User Manual

Page 16

Advertising
background image

Page 16

506488-01

Issue 1008

Figure 12

208/230V

-1-60

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Y

G

W1

R

C

Y

G

W

R

C

BLU

GRN

YEL

WHT

RED

Y

R

C

DIAGNOSTIC

MODULE

G

Y1

Y2

O

W1

EM

C1

R

HUM

INDOOR BLO

WER

MO

T

O

R

ICM BO

ARD

BLU

RED

24V

A

C

1

625

4

3

FLAME

FLAME

SENSE

GRY

BRN

BLU

ORN

RED

YEL

GRN

BLK

WHT

PUR

BLK

GRN

PUR

ORN

WHT

PUR

MAIN

LIMIT

SWITCH

R

OLLOUT

SWITCH

PRESSURE

SWITCH

A

UX.

LIMIT

SWITCH

(IF USED)

GAS

VA

LV

E

FUSE

IGNITION CONTR

OL

ORN

BLU

GRN

BLU

YEL

RED

RED

BLU

RED

YEL

CONT

A

C

T

O

R

THERMOST

A

T

YEL

YEL

HIGH PRESSURE

SWITCH

(IF USED)

L1

T1

T2

L2

C

H

F

CONDENSER

F

AN MO

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

DU

AL

CAP

A

CIT

OR

COMPRESSOR

TRANSFORMER

C

S

R

L1

CMB

BL

WR

SP

ARK

COMB

.

AIR

BLO

WER

IGNITION CONTR

OL

BLK

BLK

WHT

L2

L1

BLK

BRN

PUR

RED

RED

BLK

208V

240V

24V

INDOOR

BLO

WER

M

OTO

R

5 4 3

NO

TE:

IF ANY OF

THE ORIGINAL

WIRE IS REPLA

CED

,

THE

SAME SIZE AND

TYPE

WIRE MUST BE USED

.

USE

COPPER CONDUCT

OR ONL

Y

, MIN.

75°C

WIRE.

W

ARNING-

ELECTRIC SHOCK HAZARD

.

UNIT MUST BE GR

OUNDED

IN A

CCORD

ANCE

WITH NA

TIONAL AND LOCAL CODES

.

HEA

T ANTICIP

A

TION SETTING:

0.70 AMP

LINE

V

O

LT

A

GE FIELD INST

ALLED

SEE

BLO

WER SPEED

CHAR

T

BLK

S4

S1

K1

A3

GV1

S21

S18

S47

S10

T1

B3

B6

B4

K1-2

C12

B1

K1-1

A3

A54

B3

GR

OUND

BLU

YEL

A132

ADJUST

HEA

T COOL

NORM

(+)

(-)

(TEST)

A

B

C

D

A

B

C

D

DIA

GNOSTICS

The f

ollo

wing ignition control board LED codes will

indicate nor

mal or abnor

mal oper

ations:

SLO

W FLASH Nor

mal oper

ation, no call f

or heat.

F

AST FLASH Nor

mal oper

ation, call f

or heat.

2 FLASH System loc

k

out.

3 FLASH Pressure s

witch senses incorrect pressure

.

4 FLASH Main limit open or rollout s

witch open.

5 FLASH Flame sensed and gas v

alv

e not energiz

ed.

STEAD

Y Inter

nal f

ailure (micro-controller f

ailure;

self chec

k).

LED

YEL

E1

Blo

w

er

S

peed

C

har

t

Unit

F

a

c

tor

y

S

hipped

S

e

tt

ings

C

ooling

Input

Heat

ing

Input

AD

J

U

S

T

H

E

A

T

CO

O

L

24

68

NORM

A

B

30

68

NORM

A

A

36

68

NORM

B

A

36

90

NORM

A

A

42

83

NORM

C

C

42

110

NORM

C

C

48

83

NORM

C

B

48

110

NORM

C

B

48

138

NORM

A

B

60

83

NORM

C

A

60

110

NORM

C

A

60

138

NORM

A

A

A132

A132

BLK

Connection Diagram

Single Phase – V

ariable S

peed Motor

P/N 48107-001