Service, Specifications – Anton/Bauer HyTRON 140 User Manual

Page 16

Advertising
background image

SERVICE

In the unlikely event a HyTRON battery fails to deliver acceptable performance,
it must be returned to the Anton/Bauer Customer Support Department, the only
facility qualified and equipped to service the InterActive 2000 HyTRON batteries
and calibrate the electronic components and sensors. Any attempt by the user or
any other unauthorized persons to service this battery will surely result in
improper calibration of the electronic components resulting in severe battery
damage and/or safety hazards to the operator, in addition to voiding any/all
remaining unconditional or pro-rated warranty conditions.

Therefore:
1. DO NOT attempt to service this battery under any circumstances.
2. DO NOT send this battery for service to anyone other than the

Anton/Bauer Service Department.

3. DO NOT rebuild this battery - At the end of its useful life contact the

Anton/Bauer Service Department.

SPECIFICATIONS

HYTRON 140

HYTRON 100

HYTRON 50

OUTPUT VOLTAGE

14.4v Nominal

12 ~ 16.8v Operating

14.4v Nominal

12 ~ 16.8v Operating

14.4v Nominal

12 ~ 16.8v Operating

CAPACITY

(CELL CAPACITY)

140 WH Nominal

(10 AH Rated)

100 WH Nominal

(7 AH Rated)

50 WH Nominal

(3.5 AH Rated)

FUSE

12.5amp/125volt 12.5amp/125volt Internal

(7amp)

RECOMMENDED OPERATION

15-100 watts

15-100 watts

15-50 watts

(MAXIMUM DISCHARGE RATE)

(175 watts)

(175 watts)

(75 watts)

TYPICAL RUN-TIME

@ 20w – 7 hrs.
@ 25w – 5.6 hrs.
@ 40w – 3.5 hrs.

@ 20w - 5 hrs.
@ 25w - 4 hrs.
@ 40w – 2.5 hrs.

@ 10w - 5 hrs.
@ 20w - 21/2 hrs.
@ 25w - 2 hrs.

WEIGHT

5.5 lbs

5.5 lbs

1.9 lbs

SIZE

5

5/16

x

4

1/2

x

3

3/4

5

5/16

x

4

1/2

x

3

3/4

5

1/4

x

3

1/2

x

2

1/8

14

Advertising
This manual is related to the following products: