PARAMETERS

PROGRAM DESCRIPTION

Current

(Amperes)

Voltage

(V

olts

)

Desulphation

Soft Start

Bulk

Absorption

Recovers a

sulphated battery

Tests the battery

condition

Bulk charge

Peak charge with

minimal fluid loss

MULTI XS 25000

MODE

Desulphation

Soft Start

Bulk

Absorption

NORMAL

or

RECOND

YES

Max 10 A for 4 h until the

voltage reaches 12 V.

25 A for max 20 h.

14.4 V until 4 h after the

current dropped to 3 A,

max 12 h.

SUPPLY

XS 25000

MODE

Desulphation

Soft Start

Bulk

Absorption

PRESET YES

Max 10 A for 4 h until the

voltage reaches 12 V.

25 A for max 20 h.

14.4 V until 4 h after the

current dropped to 3 A,

max 12 h.

MULTI XT 14000

MODE

Desulphation

Soft Start

Bulk

Absorption

NORMAL

or

RECOND

YES

Max 6 A for 4 h until the

voltage reaches 24 V.

14 A for max 20 h.

28.8 V until 4 h after the

current dropped to 2 A,

max 12 h.

SUPPLY

XT 14000

MODE

Desulphation

Soft Start

Bulk

Absorption

PRESET YES

Max 6 A for 4 h until the

voltage reaches 24 V.

14 A for max 20 h.

28.8 V until 4 h after the

current dropped to 2 A,

max 12 h.