Analysis recond float pulse – AB Soft XS 25000 User Manual

Page 7

Advertising
background image

7

Analysis

Recond

Float

Pulse

Tests whether the

battery retains

the energy

Reconditioning of

a drained battery

Maintenance for

maximum

performance

Maintenance for

maximum

battery life

Analysis

Recond

Float

Pulse

Warning indication if

voltage drops to 12.6 V

in 2 minutes.

Max 15.9 V and 5 A

for 4 h for deeply

discharged batteries.

Otherwise for 30 min-

utes (only in Recond

mode).

13.8 V with max 7 A for

max 10 days.

Pulse start at 12.9 V,

max voltage 14.4 V.

13.8 V max 300 W.

Analysis

Recond

Float

Pulse

Warning indication if

voltage drops to 12.6 V

in 2 minutes.

13.8 V with max 7 A for

max 10 days.

Pulse start at 12.9 V,

max voltage 14.4 V.

Analysis

Recond

Float

Pulse

Warning indication if

voltage drops to 25.2 V

in 2 minutes.

Max 31.8 V and 3 A

for 4 h for deeply

discharged batteries.

Otherwise for 30 min-

utes (only in Recond

mode).

27.6 V with max 4 A for

max 10 days.

Pulse start at 25.8 V,

max voltage 28.8 V.

27.6 V max 300 W.

Analysis

Recond

Float

Pulse

Warning indication if

voltage drops to 25.2 V

in 2 minutes.

27.6 V with max 4 A for

max 10 days.

Pulse start at 25.8 V,

max voltage 28.8 V.

Advertising