INTRODUCTION

The APC Biopod (Figure 1) enables users to log on to a system

simply by placing their fingertip on the Biopod sensor. Use the

Biopod hardware and software to provide fingerprint

identification to access passwordprotected systems,

applications, and web sites, without password authorization.

Figure 1. The APC Biopod

Caution: Do not allow metal or sharp objects to come in contact

with the sensor surface, as they could damage the unit.

FEATURES

Attached USB cable for easy connection to laptops and

PCs

Easy-to-use Master password for all types of Windows,

application, and on-line passwords

Compatible with Microsoft Passport®

Support for Internet Explorer®

Compatible with Windows XP® Credential Manager

User-friendly graphical user interface (GUI) that is easy

to install, customize and use

Full Windows OS support including Windows 98®, ME®,

2000®, and XP® (Windows 95® is not supported)

International language support

TruePrintTM compliant

SETUP

1. Connect the Biopod.

Note: Before connecting the Biopod, remove any previously

installed biometric or related security software. To connect

the Biopod, plug the Biopod into the USB port as shown in

Figure 2. You do not have to turn the computer off.

Figure 2. Connecting the Biopod

2. Install the driver.

A. Insert the software CD.

B. The

Found New Hardware Wizard screen appears. Select Next,

then select

Search for a Suitable Driver, and select Next.

C. Check the

CD-ROM Drives check box only, and select Next.

D. Once the driver is found, select

Next to install it. The

Hardware Wizard sends a message once installation is

complete.

3. Install the APC OmniPass software.

If a previous version of the software is installed on the system,

it must be removed before installing the APC OmniPass

software.

A. Insert the APC OmniPass software CD into the CD-ROM

drive and follow the on-screen installation instructions.

B. Specify a path name for the location of software when

prompted.

C. Restart the system when prompted. An

APC OmniPass icon

appears on the Windows Control Panel, the Windows Start

menu, and in the task bar.

4.

Select the

Enroll Wizard to add fingerprints to the database.

The Enroll Wizard initial screen appears (Figure 3).

Figure 3. The Enroll Wizard Initial Screen

5.

Select the

Enroll button. The Verify Password screen

(Figure 4) appears.

Figure 4. The Verify Password Screen

6.

On some systems, the current Windows user name is filled

in. (Windows 98/ME users must type the user name.) If a

user does not have a Windows user name, one is created

during this process.

Enter the Windows password in the

Password field. This is

the same password that is used to log into Windows.

Select

Next to continue or Cancel to exit.

The

Choose a Finger screen (Figure 5) appears. Select a

finger to enroll by highlighting and selecting the finger. A

green check mark indicates that a particular finger has

already been enrolled.

Figure 5. The Choose a Finger Screen

Advertising