Using Graphing Multimeter (GMM)

Making Connections

INPUT A is used for all GMM tests just except the RPM measurement. The probes and test leads to be used depend
on t he type of test performed. When you select cert ain GMM tests, a connect ion help screen will guide you by
pressing HELP ( ). This tells you which probe or test lead to use and where to connect it.

Function Key Labels for Each Test

Testing Volt DC, AC

You can stop graphing by pressing HOLD key on the instrument.

5-9

MAIN MENU

SELECTED VEHICLE
CHANGE VEHICLE
COMPONENT TESTS
SCOPE

GRAPHING MULTIMETER

VEHICLE DATA
INSTRUMENT SETUP

GRAPHING MULTIMETER MENU

VOLT DC, AC

OHM / DIODE / CONTINUITY
RPM
FREQUENCY
DUTY CYCLE
PULSE WIDTH
DWELL
IGNITION PEAK VOLTS
IGNITION BURN VOLTS
IGNITION BURN TIME
INJECTOR PEAK VOLTS
INJECTOR ON TIME
AMP DC, AC
TEMPERATURE °C, °F
LIVE

Vertical and Horizontal Scaling

The vertical and horizontal ranges in GMM displays are manually adjustable by using the Four Way arrow keys.

The vertical ranges available in GMM displays vary with the measurement being graphed, and generally cover the
possible output range of the measurement.
The time ranges available for GMM displays range from 5 sec. to 24 hrs. per display.
Auto-Power-Off will not occur during the GMM mode, but t o graph for periods of 5 min and longer, operate the
instrument from external power because operating endurance on internal power is limited to about 4 hours with fresh
batteries.

5-8

Figure 13. Changing Vertical and Horizontal Ranges

Code

DC VOLT

AC VOLT

AC+DC VOLT

OHM

DIODE

CONTINUITY

RPM

FREQUENCY

DUTY CYCLE

PULSE WIDTH

DWELL

IGNITION PEAK VOLTS

IGNITION BURN VOLTS

IGNITION BURN TIME

INJECTOR PEAK VOLTS

INJECTOR ON TIME

TEMPERATURE

LIVE

Measurement

DC Average

AC Average

AC+DC Average

Ohms

Diode drop

Continuity

RPM

Frequency

Duty Cycle

Pulse Width

Dwell

Ignition Peak Volts

Ignition Burn Volts

Ignition Burn Time

Injector Peak Volts

Injector On Time

Temperature °C, °F

Live

Graphing Type

Continuous

Continuous

Continuous

Continuous

Continuous

Continuous

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Cycle by Cycle

Continuous

Direct input samples

MENU ( )

Press to reset maximum
and minimum.

Press to start plotting a new
g rap h as new samples are
acquired.

Press to measure DC
voltage.

Press to measure AC
true rms voltage.

Press to measure AC+DC true rms voltage.

GMM VOLT

MAX/MIN REPEAT

DC

AC AC+DC

RESET TEST

Advertising