Testing Frequency, Duty Cycle, or Pulse Width

Testing Secondary Ignition Peak Volts, Burn Volts, and Burn Time

5-11

Press to test the signal
frequency in Hz.

P ress t o te st the dut y cycle of th e
signal.
If you select , the duty cycle of the
negative-going pulse is displayed.
If you select , the duty cycle of the
positive-going pulse is displayed.

Press to test the pulse width of the
signal.
If you select , th e width of th e
negative-going pulse is displayed.
If you select , th e width of th e
positive-going pulse is displayed.

GRAPHING MULTIMETER

FREQUENCY

DUTY CYCLE

PULSE WIDTH

GRAPHING MULTIMETER

IGNITION PEAK VOLTS

IGNITION BURN VOLTS

IGNITION BURN TIME

Testing Resistance, Diode, and Continuity

Use this menu option to test resistance, diode forward voltage, and the continuity of wiring and connections. Connect
the test lead tip and test lead ground across the object to be tested.

OFL is displayed when the resistance is outside the instrument’s maximum range. This occurs when the resistance
of the sensor is too high or the connection to the sensor is interrupted or open.

To test a diode, the instrument sends a small current through the diode to test the voltage across it. Depending on
the type of diode, this voltage should be in the range from 300 to 600 mV. A diode that has an internal short will
display about 0 V. OFL is displayed when the diode is defective or when it is connected in reverse. If you are not
certain about the polarity of the diode, try the reverse connection. If this also displays OFL, the diode is defective. A
good diode must display OFL when connected in reverse.

Measuring RPM

The instrument automatically scales and displays the waveform on the screen. Connect the Inductive Pickup to the
COM/TRIGGER input terminals and clamp the pickup probe on the spark plug wire close to the spark plug.

and keys are used to set the number of Spark Signal P ulses to t he instrument per 720 (two crank shaft

revolutions). n = 1, 2, 3, 4, 5, 6, 8, 10, or 12

5-10

Press to test continuity of wiring and
connections.
If you select OPEN, the instrument beeps
when the tested connection is open.
If you select CLOSE, it beeps when the
tested connection is closed.

MENU ( )

MENU ( )

Press to invert th e displayed ignition
waveform.

Press to measure
resistance.

Press to start plotting a new graph
as new samples are acquired.

Press to decrease.

Press to increase.

Press to restore the d efault value
settings stored in VEHICLE DATA.

GMM OHM

CONTINUTY

OHM

OPEN CLOSE

GMM FREQUENCY

%

ms

Hz

GMM DUTY CYCLE

%

ms

Hz

GMM PULSE WIDTH

%

ms

Hz

GMM RPM

n

DEFAULT REPEAT

1

720 SETUP TEST

RPM TRIG

Press to adjust the built-in
4 step trigger levels.
Default is Level 2.

2

GMM IGNITION PEAK VOLTS

INVERT REPEAT MAX/MIN

TEST RESET

GMM IGNITION BURN VOLTS

GMM IGNITION BURN TIME

OFF

INVERT REPEAT MAX/MIN

TEST RESET

OFF

INVERT REPEAT MAX/MIN

TEST RESET

OFF

Press to test diodes.

Advertising