Storage Essentials 5.00.01 User Guide 413

The management server does not receive SNMP v1 traps from Sun StorEdge switches that have

the SNMPv1 agent.

If you want the management server to be able to receive events from a NetApp Filer, you must

add the IP address of the management server CIMOM to the NetApp configuration. The

management server CIMOM runs on the same computer running the management server by

default.

Event Manager displays events from all elements regardless of the user’s organization.

Event Manager displays events it receives from CNT InVsn Enterprise Manager. As of version 9.5

of CNT InVsn Enterprise Manager, InVsn Enterprise Manager does not provide events to the

management server. As future versions of CNT InVsn Enterprise Manager provide event support,

the management server will be able to provide information about those events.

Issues with Brocade Switches

Event Manager does not display events from Brocade switches with the firmware version 3.0.

This firmware version is not supported by Event Manager. You can, however, specify Event

Manager not to display events from additional firmware versions. See ”

Filtering Events

” on

page 420.

Events from Brocade Fabric Watch have “Fabric watch:” in their heading, as shown in the

following example:

Fabric watch: threshold is below low boundary, Value:30 Class: Environment
ClassArea: Temperature Index: 1 EventType: Below EventState: Faulty

Issues with McDATA and Connectrix Switches

If you discovered McDATA and/or Connectrix switches through SWAPI, Event Manager does not

report events for switch hardware failures, except for those regarding switch ports (port

off-line/port online).

If you are not receiving events from McDATA and Connectrix switches discovered through SNMP,

make sure you have the correct port set for receiving SNMP traps. You must also configure the

proxy or each switch (depending on your configuration for discovery) to send the SNMP traps to

the correct port on the management server. See ”

Discovering McDATA and EMC Connectrix

Switches

” on page 41 for more information.

If you want the management server to receive SNMP events from Connectrix or McDATA

switches, do one of the following:
• If you discovered Connectrix Manager or EFC Manager, only enable SNMP trap forwarding

to the management server on the Connectrix Manager or EFC Manager, not on the

individual switches. Connectrix Manager or EFC Manager should be configured to forward

SNMP traps to the IP address of the management server, and the community string should

match the user ID you used to discover Connectrix Manager or EFC Manager.

• If you discovered Connectrix or McDATA switches directly, enable SNMP trap forwarding on

the switches, not on any other management software. The switches should be configured to

forward SNMP traps to the IP address of the management server, and the community string

should match the user ID you used to discover the Connectrix or McDATA switches.

Viewing Event Details

To access event details: