HP 4000.6000.8000 Enterprise Virtual Arrays User Manual

Page 8

Advertising
background image

0.3.en.06 UNRECOVERABLE condition—No blowers installed .........................................123

Temperature conditions.....................................................................................................123

0.4.en.01 NONCRITICAL condition—High temperature...................................................123
0.4.en.02 CRITICAL condition—High temperature...........................................................124
0.4.en.03 NONCRITICAL condition—Low temperature....................................................124
0.4.en.04 CRITICAL condition—Low temperature............................................................124
0.4.en.05 UNRECOVERABLE condition—High temperature .............................................124

EMU conditions...............................................................................................................125

Resetting the EMU.......................................................................................................125
07.01.01 CRITICAL condition—EMU internal clock...........................................................125
07.01.02 UNRECOVERABLE condition—EMU interrupted ................................................125
0.7.01.03 UNRECOVERABLE Condition—Power supply shutdown .....................................126
0.7.01.04 INFORMATION condition—EMU internal data.................................................126
0.7.01.05 UNRECOVERABLE condition—Backplane NVRAM ...........................................126
0.7.01.10 NONCRITICAL condition—NVRAM invalid read data .......................................126
0.7.01.11 NONCRITICAL condition—EMU NVRAM write failure .......................................126
0.7.01.12 NONCRITICAL condition—EMU cannot read NVRAM data ...............................127
0.7.01.13 UNRECOVERABLE condition—EMU load failure ...............................................127
0.7.01.14 NONCRITICAL condition—EMU enclosure address ...........................................127
0.7.01.15 UNRECOVERABLE condition—EMU hardware failure ........................................127
0.7.01.16 INFORMATION condition—EMU internal ESI data corrupted ..............................127
0.7.01.17 UNRECOVERABLE condition—Power shutdown failure........................................128
0.7.01.18 UNRECOVERABLE condition—EMU hardware failure.........................................128
0.7.01.19 UNRECOVERABLE condition—EMU ESI driver failure.........................................128

Transceiver conditions.......................................................................................................128

0.F.en.01 CRITICAL condition—Transceiver incompatibility ...............................................129
0.F.en.02 CRITICAL condition—Transceiver data signal lost ..............................................129
0.F.en.03 CRITICAL condition—Transceiver fibre channel drive enclosure bus fault...............129
0.F.en.04 CRITICAL condition—Transceiver removed........................................................129
0.F.en.05 CRITICAL condition—Invalid fibre channel character..........................................130

CAN bus communication port conditions............................................................................130

Resetting the EMU.......................................................................................................130
1.1.03.01 NONCRITICAL condition—Communication error...............................................130
1.1.03.02 INFORMATION condition—Recovery completed...............................................130
1.1.03.03 INFORMATION condition—Overrun recovery...................................................131

Voltage sensor and current sensor conditions.......................................................................131

1.2.en.01 NONCRITICAL condition—High voltage .........................................................131
1.2.en.02 CRITICAL condition—High voltage .................................................................131
1.2.en.03 NONCRITICAL condition—Low voltage ..........................................................131
1.2.en.04 CRITICAL condition—Low voltage ..................................................................132
1.3.en.01 NONCRITICAL condition—High current ..........................................................132
1.3.en.02 CRITICAL condition—High current ..................................................................132

Backplane conditions.......................................................................................................132

8.2.01.10 NONCRITICAL condition—Backplane NVRAM read .........................................132
8.2.01.11 NONCRITICAL condition—Backplane NVRAM write failure ...............................132
8.2.01.12 NONCRITICAL condition—Backplane NVRAM read failure ...............................132
8.2.01.13 NONCRITICAL condition—Backplane WWN is blank.......................................132

I/O Module conditions.....................................................................................................133

8.7.en.01 CRITICAL condition—I/O module unsupported ................................................133
8.7.en.02 CRITICAL condition—I/O module communication ............................................133
8.7.en.10 NONCRITICAL condition—I/O module NVRAM read ......................................133
8.7.en.11 NONCRITICAL condition—I/O module NVRAM write........................................133
8.7.en.12 NONCRITICAL condition—I/O Module NVRAM read failure .............................134
8.7.en.13 NONCRITICAL condition—I/O module removed...............................................134

Host conditions................................................................................................................134

8

Contents

Advertising