Setting Power Supply Requirements Override

The server can operate workloads and configurations with the required power supplies installed.
You can modify the server's power supply requirements to allow the server to operate with one
power supply and be redundant or with two power supplies and be redundant with three power
supplies. You should only override the normal power supply requirements if they use the HP Power
Calculator to confirm that their system's configuration can operate with the selected power supply
requirements.

NOTE:

Use the HP Power Advisor to confirm the system's power supply requirements before

enabling any of the options that override the default power supply requirements.

To set power supply requirements override:
1.

From the System Utilities screen, select System Configuration

→BIOS/Platform Configuration

(RBSU)

→Advanced Options→Power Supply Requirements Override and press Enter.

2.

Select one of the following options:

Default Power Supply Requirements (default)

Configure for 1 minimum required, 2 required for redundancy

Configure for 2 minimum required, 3 required for redundancy

Configure for 2 minimum required, 4 required for redundancy

Configure for 3 minimum required, 4 required for redundancy

Configure for 4 minimum required, no redundancy

Accessing the BIOS/Platform Configuration (RBSU) menu