Powering off the storage system – HP LeftHand P4000 Virtual SAN Appliance Software User Manual

Page 24

Advertising
background image

4.

Select Reboot to perform a software reboot without a power cycle.

5.

Click OK.

The storage system starts the reboot in the specified number of minutes. The reboot takes
several minutes.

6.

Search for the storage system to reconnect the CMC to the storage system once it has finished
rebooting.

See

“Finding storage systems” (page 17)

.

Powering off the storage system

1.

Log in to the storage system.

2.

Select Storage System Tasks on the Details tab and select Power Off or Reboot.

3.

Select Power Off.

The button changes to Power Off.

4.

In the minutes field, enter the number of minutes before the powering off should begin.

Enter any whole number greater than or equal to 0. If you enter 0, the storage system powers
off shortly after you confirm the power off.

NOTE:

If you enter 0 for the value when powering off, you cannot cancel the action. Any

value greater than 0 allows you to cancel before the power off actually takes place.

5.

Click Power Off.

Figure 6 Confirming storage system power off

Depending on the configuration of the management group and volumes, your volumes and
snapshots can remain available.

24

Working with storage systems

Advertising
This manual is related to the following products: