Figure 19: configuring open trunking, 19 configuring open trunking – HP StorageWorks 2.64 Director Switch User Manual

Page 75

Advertising
background image

Configuring the Product

75

Embedded Web Server User Guide

Note:

For the Director 2/140, ports are displayed through several pages in groups of

32. To configure all of the ports, make sure you go through each set. You must click

Activate for each view before moving to the next.

To configure Open Trunking:

1. Choose Configure from the navigation panel.

2. Choose the Performance tab and the Open Trunking tab. The Open

Trunking tab view displays (

Figure 19

).

Figure 19: Configuring Open Trunking

3. Choose Enabled in the Open Trunking State drop down list.

4. Choose Enabled or Disabled from the Unresolved Congestion Event

Notification drop down list. If enabled, an unresolved congestion entry is
made in the event log and, if SNMP is configured, an SNMP trap is generated.
Unresolved congestion occurs when a flow cannot be rerouted to another link
because it would exceed the other link's threshold.

5. Choose Enabled or Disabled from the Backpressure Event Notification

drop down list. If enabled, a backpressure entry is made in the event log and,
if SNMP is configured, an SNMP trap is generated. Backpressure occurs
when the threshold of unavailable BB_Credits is exceeded for any link.

6. Specify a value for the Low BB Credit Threshold option, if desired.