Hp surestore dlt1i, Dlt vs80i, Hp surestore dlt vs80i tape drive – HP StorageWorks DLT VS80 Tape Drive User Manual

Page 17: Hp surestore dlt vs80i, Features, Specifications, Physical specification, Power requirements, Performance, Operating limits

Advertising
background image

hp surestore DLT1i

hp learning products

http://www.hp.com/support/tape

may have a later version


data protection

index of topics

contact hp

home page

before you start

operation

cartridge care

cleaning

specifications

DLT VS80i

DLT VS80e

DLT VS80m

media compatibility

diagnostics

troubleshooting

FAQs

SCSI configuration

UNIX configuration

ordering supplies

installing drivers

hp surestore DLT VS80i

contents of this section

features

specifications

physical specification

power requirements

performance

operating limits

non-operating limits

safety and electromagnetic compatibility

features

The HP Surestore DLT VS80 tape drive provides affordable 80GB backup to IT
managers with mid-range servers. The 6MB/s compressed transfer rate provides
backup in under 4 hours. DLT technology appeals to customers looking for
reliable and scalable backup.

Your new tape drive provides the following key features:

Proven DLT technology

Up to 80GB (compressed) on a single tape cartridge

Transfer rate of 6MB/s (compressed)

Read compatible with DLT4000 data

Technology scalable to higher capacities and transfer rates

Compatibility with all key backup software applications

TapeSense System™ to improve reliability by rejecting damaged media

Roller design to minimize lateral tape movement

TapeAlert

support for worry-free backup

HP Library & Tape Tools

software to verify successful installation and

troubleshoot problems

HP Instant Support

for web-based problem identification, diagnosis and

resolution providing fast, easy-to-use online solutions to problems.

Ultra wide SCSI-2 interface

3-year, next-day, unit exchange

specifications

physical specification

dimensions

148.2 mm (5.83") W (with bezel)
43.8 mm (1.73") H (with bezel)
221.0 mm (8.70") D (with bezel)

weight 1.35 kg (2.98 lbs)

power requirements

power consumption

+5V @ 1.6A steady state
+12V @ 0.65A steady state
+5V @ 1.9A (max)
+12V @ 2.7A (max)

performance

interface Ultra wide SCSI-2

recording format DLT1

media DLTtape IV

capacity 40 GB (native)

sustained transfer rate

native 3 MB/sec
compressed 6 MB/sec (assumes 2:1
compression)

burst transfer rate 20 MB/sec (Ultra wide SCSI-2)

file access time (from BOT)

68 sec typical
135 sec maximum

load to BOT 59 sec (slightly longer for blank tapes)

unload from BOT 17 sec

rewind time

68 sec typical
135 sec maximum

rewind tape speed 4.1 m/sec (160 in/sec)

operating limits

temperature 10°C to 40°C (50°F to 104°F)

humidity

20% to 80% RH (non-condensing)
10%/hr maximum operating humidity rise

maximum wet bulb temperature 25°C

temperature gradient 11°C per hour (across range)

operating altitude -0.15 to 9 km (-500 to 30,000 ft)

vibration 0.25g 5-500 Hz

shock survival 10g 10ms (half sine)

non-operating limits

temperature -40°C to 66°C (-40°F to 151°F)

humidity 10% to 95% RH (non-condensing)

temperature rise

20°C per hour with 5 degree margin
(across range)

humidity rise 10%/hr

non-operating altitude N/A

vibration 1g 10-500 Hz

shock survival

40G 10ms (square wave)
140G 2ms (half sine)

safety and electromagnetic compatibility


UL 1950, 3rd edition Information Technology Equipment (ITE)
CSA-C22.2 No. 950-95 Safety of Information Technology Equipment
FCC Rules and Regulations, Part 15--Radio Frequency Devices,
Subpart B--Unintentional Radiators, Class B
Industry Canada (ICES), Radio Interference Regulation, Digital
Apparatus, Class B
C-TICK, AS/NZS A3548, Radio Frequency Devices Class B
CISPR Publication 22 (1985), Class B
EN 55022: 1998, CISPR Publication 22 (1997), CISPR Publication 22
(1993) (U.S.A.), Radiated and Conducted Emissions
EN55024: 1998, CISPR Publication 24 (1997), IEC61000-4-2: 1995,
IEC61000-4-3: 1995, IEC61000-4-5: 1995, IEC61000-4-6: 1996,
IEC61000-4-8: 1993, IEC61000-4-11: 1994, Immunities.


CE-Mark comprised of the following requirements:

EN60950/A11: 1997, IEC60950/A4: 1996, Safety of Information
Technology Equipment including Electrical Business Equipment
EN55082-1/IEC1000-4-2, 1000-4-3, 1000-4-4, Electromagnetic
Compatibility for Industrial-Process Measurement and Control
Equipment:

Part 2 - Electrostatic Discharge (ESD) Requirements
Part 3 - Radiated Electromagnetic Field Requirements
Part 4 - Electrical Fast Transient/Burst (EFT) Requirements


© 2001, Hewlett-Packard Company

file:///C|/Documents%20and%20Settings/topher.COL-SPRINGS/Desktop/dltvs80%20manual/document/dltvs80/user/reseller/eng/dltvs80i.htm [11/29/2001 8:33:59 AM]

Advertising
This manual is related to the following products: