Spin down, Spin up, Start backup path – HP Integrity NonStop J-Series User Manual

Page 124: Start disk, Start primary path, Start volume, Stop backup path, Stop disk

Advertising
background image

NOTE:

With OSM Low-Level Link T0633 AAQ and later, you can also save system configuration

files on the system console. Those saved configurations are not displayed as attributes values in
the OSM Service Connection, but can be used during the system load operations in the Low-Level
Link. For more information, see the OSM Low-Level Link online help.

Spin Down

Stops the physical spinning of the disk drive. This should be done before removing a disk drive.
Both paths must be down for the action to succeed.

Spin Up

Starts the physical spinning of the disk drive.

Start Backup Path

Starts the backup path to this disk drive. When the Start action completes, the backup path is in
the Started state.

This action fails if both paths to this disk are down and the mirrored disk is Up. For more information,
see

Start Disk

.

Start Disk

Use this action to start all paths to the disk drive only when:

The disk paths are in a Down state. (Hard Down states require a reset action, either

Reset

Disk

,

Reset Primary Path

, or

Reset Backup Path

as appropriate.)

Its mirrored disk is not currently Up. The Start Disk action is designed to fail if the mirrored
disk is already in an Up state because the mirror and primary disk volumes can have different
data and require a revive operation. To revive and bring up the disks properly, use the OSM

Start Volume

action or SCF START DISK command.

When the action completes successfully, all paths to the disk are in the Started state.

Start Primary Path

Starts the primary path to this disk drive. When the Start action completes, the primary path is in
the Started state.

This action fails if both paths to this disk are down and the mirrored disk is Up. For more information,
see

Start Disk

.

Start Volume

Starts all paths for both the primary and mirror drives of this volume unless they are in a Hard
Down state. Disk paths in a Hard Down state require a reset action first (either

Reset Disk

,

Reset

Primary Path

, or

Reset Backup Path

as appropriate).

Stop Backup Path

Terminates the backup path to the disk. When the Stop action finishes, the path is in a Down state.
If the disk drive is currently in use, a dialog box warns you and asks whether or not you want to
continue with the action.

Stop Disk

Terminates all paths for this disk drive. When the Stop action finishes, the paths are in a Down
state. If the disk drive is currently in use, a dialog box warns you and asks whether or not you
want to continue with the action.